Skip to content
The text

New York S 10200, Introduced: Provides for energy efficiency improvements to certain windows; relates to certain alterations concerning windows and HVAC equipment in multiple dwellings.

The text Dorworth News extracted from the kept copy

Download the original (HTML, 59 KB)

Fingerprint
ef53f10dd59c29a9b4c4b46bc66b2c37dd09fdb48d62f21f7c137123dc933f57SHA-256 of the kept copy exactly as received.
Original
https://assembly.state.ny.us/leg/?default_fld=&bn=S10200&term=2025&Summary=Y&Actions=Y&Text=Y&Committee%26nbspVotes=Y&Floor%26nbspVotes=Y#S10200
The text
64 paragraphs, read from the kept copy, kept . The words are the document’s own; the layout is the site’s. The page’s menus, header and footer are left out.
1

Bill No.:

2

Summary

3

Actions

4

Committee Votes

5

Floor Votes

6

Memo

7

Text

8

LFIN

9

Chamber Video/Transcript

10

S10200 Summary:

11
12
13
14
15
16
17
18

Go to top

19

S10200 Actions:

20
21
22
23
24
25
26
27
28

Go to top

29

S10200 Committee Votes:

30

Go to top

31

S10200 Floor Votes:

32

There are no Assembly votes for this bill in this legislative session.

33

Go to top

34

S10200 Text:

35

STATE OF NEW YORK ________________________________________________________________________

36

10200--A Cal. No. 1510

37

IN SENATE

38

May 5, 2026 ___________

39

Introduced by Sens. KAVANAGH, SALAZAR -- read twice and ordered printed, and when printed to be committed to the Committee on Housing, Construction and Community Development -- committee discharged and said bill committed to the Committee on Rules -- ordered to a third reading, amended and ordered reprinted, retaining its place in the order of third reading

40

AN ACT to amend the multiple dwelling law, in relation to energy effi- ciency improvements and certain alterations to multiple dwellings

41

The People of the State of New York, represented in Senate and Assem- bly, do enact as follows:

42

1 Section 1. Section 4 of the multiple dwelling law is amended by 2 adding a new subdivision 45 to read as follows: 3 45. "HVAC equipment" is heating, ventilation and air conditioning 4 equipment. 5 § 2. Subdivision 5 of section 30 of the multiple dwelling law is 6 amended to read as follows: 7 5. No multiple dwelling shall be so altered as to diminish the light 8 or ventilation of any room or public hall or stairs in any way not 9 approved by the department, except that: 10 a. Where an existing window in any room, public hall or stairs is 11 replaced with a window assembly having a lower coefficient of heat tran- 12 smittance, such light and ventilation may be reduced by not more than 13 twenty-five percent below the minimum otherwise required by this chap- 14 ter. 15 b. Where HVAC equipment is installed in an existing window, such light 16 and ventilation may be reduced by not more than twenty-five percent 17 below the minimum otherwise required by this chapter. 18 c. Where both an existing window is replaced with a window assembly in 19 accordance with paragraph a of this subdivision and HVAC equipment is 20 installed in such window assembly, such light and ventilation may be 21 reduced by not more than thirty-three percent below the minimum other- 22 wise required by this chapter.

43

EXPLANATION--Matter in italics (underscored) is new; matter in brackets [ ] is old law to be omitted. LBD15756-03-6

44

S. 10200--A 2

45

1 § 3. Paragraph (a) of subdivision 8 of section 30 of the multiple 2 dwelling law, as amended by chapter 559 of the laws of 1995, is amended 3 to read as follows: 4 (a) The windows in every room, except a water-closet compartment, 5 bathroom, or cooking space less than eighty square feet in floor surface 6 area, shall have a total area at least one-tenth of the floor surface 7 area of such room [and every window in such a room, including a 8 mullioned casement window, shall be at least twelve square feet in area] 9 except that: 10 (1) Where an existing window in any such room is replaced with a 11 window assembly having a lower coefficient of heat transmittance, such 12 window area may be reduced by not more than twenty-five percent below 13 the minimum otherwise required by this paragraph. 14 (2) Where HVAC equipment is installed in an existing window, such 15 window area may be reduced by not more than twenty-five percent below 16 the minimum otherwise required by this paragraph. 17 (3) Where both an existing window is replaced with a window assembly 18 in accordance with subparagraph one of this paragraph and HVAC equipment 19 is installed in such window assembly, such window area may be reduced by 20 not more than thirty-three percent below the minimum otherwise required 21 by this paragraph. 22 § 4. Subdivision 4 of section 31 of the multiple dwelling law is 23 amended to read as follows: 24 4. Dining bays with a floor area of fifty-five square feet or less 25 shall not be considered as rooms or alcoves and shall not be required to 26 comply with the provisions of section thirty-two. Every such dining bay 27 shall be equipped with such appropriate permanent fittings as may be 28 required by the department and shall be provided with at least one 29 window opening directly upon a street or upon a lawful yard, court or 30 space above a setback. Such window shall have an area of at least one- 31 eighth of the floor area of such dining bay except that: 32 a. Where an existing window in any such dining bay is replaced with a 33 window assembly having a lower coefficient of heat transmittance, such 34 window area may be reduced by not more than twenty-five percent below 35 the minimum otherwise required by this subdivision. 36 b. Where HVAC equipment is installed in an existing window, such 37 window area may be reduced by not more than twenty-five percent below 38 the minimum otherwise required by this subdivision. 39 c. Where both an existing window is replaced with a window assembly in 40 accordance with paragraph a of this subdivision and HVAC equipment is 41 installed in such window assembly, such window area may be reduced by 42 not more than thirty-three percent below the minimum otherwise required 43 by this subdivision. 44 § 5. Paragraph c of subdivision 3 of section 33 of the multiple dwell- 45 ing law, as amended by chapter 366 of the laws of 1957, is amended to 46 read as follows: 47 c. Every kitchenette constructed after July first, nineteen hundred 48 forty-nine, shall be provided with a window opening upon a street or 49 upon a yard, court, shaft, or upon any space above a setback. 50 (1) Such window shall be at least one foot wide, have a total area of 51 at least three square feet and be at least ten per centum of the super- 52 ficial floor area of such kitchenette except that: 53 A. Where an existing window in any such kitchenette is replaced with 54 an assembly having a lower coefficient of heat transmittance, such 55 window area may be reduced by not more than twenty-five percent below 56 the minimum otherwise required by this subparagraph.

46

S. 10200--A 3

47

1 B. Where HVAC equipment is installed in an existing window, such 2 window area may be reduced by not more than twenty-five percent below 3 the minimum otherwise required by this subparagraph. 4 C. Where both an existing window is replaced with a window assembly in 5 accordance with clause A of this subparagraph and HVAC equipment is 6 installed in such window assembly, then such window area may be reduced 7 by not more than thirty-three percent below the minimum otherwise 8 required by this subparagraph. 9 (2) In lieu of such window, such kitchenette may be provided with 10 mechanical ventilation to provide at least six changes per hour of the 11 air volume of such kitchenette or, when such kitchenette is on the top 12 story, may have a skylight at least one foot wide with a total area of 13 at least four square feet or one-eighth of the area of the kitchenette, 14 whichever is greater, and shall have ventilating openings of at least 15 one-half of the area of the skylight. 16 § 6. The opening paragraph and paragraph d of subdivision 1 of section 17 34 of the multiple dwelling law, the opening paragraph as amended by 18 chapter 874 of the laws of 1956, are amended to read as follows: 19 In any multiple dwelling erected after April eighteenth, nineteen 20 hundred twenty-nine, every room in a cellar or basement shall have a 21 permit as provided in [subdivision five of] section three hundred and, 22 except as provided in subdivision six of this section, shall comply with 23 the following conditions: 24 d. Every such room shall have a window or windows complying with the 25 requirements of section thirty. 26 (1) The aggregate area of windows in each such room, except as 27 provided in paragraph f, shall be at least one-eighth of the horizontal 28 area of the room except that: 29 A. Where an existing window in any such room is replaced with a window 30 assembly having a lower coefficient of heat transmittance, such window 31 area may be reduced by not more than twenty-five percent below the mini- 32 mum otherwise required by this paragraph. 33 B. Where HVAC equipment is installed in an existing window, such 34 window area may be reduced by not more than twenty-five percent below 35 the minimum otherwise required by this paragraph. 36 C. Where both an existing window is replaced with a window assembly in 37 accordance with clause A of this subparagraph and HVAC equipment is 38 installed in such window assembly, such window area may be reduced by 39 not more than thirty-three percent below the minimum otherwise required 40 by this paragraph. 41 (2) Each such window shall be constructed so that the upper half of 42 its area can be opened, and shall open upon a street, court or yard. The 43 underside of the top stop-bead of each such window shall be within 44 twelve inches of the ceiling. [One window in each such room shall have 45 an area of at least twelve square feet.] 46 § 7. Subdivision 1 of section 36 of the multiple dwelling law is 47 amended to read as follows: 48 1. In every multiple dwelling erected after April eighteenth, nineteen 49 hundred twenty-nine, one at least of the required windows provided to 50 light each public hall or part thereof shall be at least two feet six 51 inches wide and five feet high except that where existing windows are 52 replaced with window assemblies having a lower coefficient of heat tran- 53 smittance, such openings may be reduced in area by not more than twen- 54 ty-five percent. Every required window in such a hall shall open upon a 55 street, court, yard or space above a setback. On the top story of such a

48

S. 10200--A 4

49

1 dwelling a ventilating skylight of the same dimensions shall be accepted 2 in lieu of a window for that story. 3 § 8. Paragraph h of subdivision 1 of section 76 of the multiple dwell- 4 ing law, as amended by chapter 642 of the laws of 1964, is amended to 5 read as follows: 6 h. Every water-closet compartment, bathroom and general or public 7 toilet room, and every other room containing one or more water-closets 8 or urinals, except as specifically provided otherwise in this section, 9 shall have at least one window opening upon a street or lawful court, 10 yard or space above a setback. Every such window shall be at least three 11 square feet in area and shall be made so that half its area can be read- 12 ily opened, except that where an existing window is replaced with a 13 window assembly having a lower coefficient of heat transmittance, such 14 window area may be reduced to two and one-quarter square feet. 15 § 9. Paragraph f of subdivision 2 of section 107 of the multiple 16 dwelling law is amended to read as follows: 17 f. If a window to the outer air is provided in any such public vesti- 18 bule or hall, such vestibule or hall shall nevertheless be ventilated as 19 provided in paragraph e, except that if such a window [has] is readily 20 accessible to the outer air to the extent of at least five and one-half 21 square feet of its area, no vent flues need be provided within a 22 distance of forty feet from each side of such window having a glazed 23 area of at least twelve square feet and at least one tenth of the super- 24 ficial floor area of the vestibule or hall, [readily accessible to the 25 outer air to the extent of at least five and one-half square feet of its 26 area, no vent flues need be provided within a distance of forty feet 27 from each side of such window] or, where an existing window is replaced 28 with a window assembly having a lower coefficient of heat transmittance, 29 such replaced window may be reduced to the greater of a glazed area of 30 at least ten square feet or at least one-twelfth of the floor area of 31 the vestibule or hall. 32 § 10. Subdivision 4 of section 148 of the multiple dwelling law, as 33 amended by chapter 446 of the laws of 1951, is amended to read as 34 follows: 35 4. Except in the case of an interior enclosed stair separated from and 36 directly accessible to the public hall by a self-closing fireproof door 37 and except as provided in subdivision five, there shall be provided to 38 light and ventilate every stair at every story a window or windows open- 39 ing on a street, court, yard or space above a setback. At least one such 40 window shall be at least two feet six inches wide and five feet high 41 unless it opens on a street, in which case its minimum height shall be 42 four feet. The aggregate area of such window or windows at each story 43 shall be at least eighteen square feet[. On] except that where an exist- 44 ing window is replaced with a window assembly having a lower coefficient 45 of heat transmittance, the aggregate area of such window may be reduced 46 by up to twenty-five percent and on the top story a ventilating skylight 47 may be substituted for a window. At the entrance story or at the roof 48 level a sash door, such as described in section thirty-five, opening to 49 the outer air may be substituted for such window. 50 § 11. Paragraph b of subdivision 2 of section 171 of the multiple 51 dwelling law is amended to read as follows: 52 b. To reduce the room or window area of any converted dwelling or make 53 any other alteration therein if such alteration decreases the light, 54 ventilation, fire protection or sanitation thereof except that: 55 (1) Where an existing window in any such room is replaced with a 56 window assembly having a lower coefficient of heat transmittance, window

50

S. 10200--A 5

51

1 areas and light and ventilation may be reduced by not more than twenty- 2 five percent below the minimum otherwise required by this chapter. 3 (2) Where HVAC equipment is installed in an existing window, such 4 window area, light, and ventilation may be reduced by not more than 5 twenty-five percent below the minimum otherwise required by this chap- 6 ter. 7 (3) Where both an existing window is replaced with a window assembly 8 in accordance with subparagraph one of this paragraph and HVAC equipment 9 is installed in such window assembly, such window area, light, and 10 ventilation may be reduced by not more than thirty-three percent below 11 the minimum otherwise required by this chapter. 12 § 12. Subdivisions 1, 2 and 3 of section 173 of the multiple dwelling 13 law, subdivision 2 as amended by chapter 566 of the laws of 1954, are 14 amended to read as follows: 15 1. Except as provided in [subdivision four of] section one hundred 16 seventy-seven every living room shall have one or more windows opening 17 directly upon a street or upon a yard or court with dimensions conform- 18 ing to those specified in section one hundred seventy-two, or upon an 19 inner court or shaft three feet nine inches or more in width and eight 20 feet or more in length. 21 2. a. Such windows shall be so located as to light properly all 22 portions of the room and in each room shall have an aggregate glazed 23 area of at least one-tenth of the floor area of the room, unless in the 24 opinion of the department such room is already adequately lighted and 25 ventilated. The top of at least one window in each living room shall be 26 seven feet or more above the floor except when such room is in the base- 27 ment or on the top story, in which case the top of at least one window 28 shall be six feet or more above the floor. Every such window shall be 29 twelve square feet or more in area, and shall be so constructed that 30 one-half or more of its area may be opened. However, such window need 31 not be twelve square feet in area provided that each room shall have an 32 aggregate glazed window area of at least one-eighth of the superficial 33 floor area of the room. 34 b. Notwithstanding any inconsistent provision of this subdivision: 35 (1) Where any such existing window in any such room is replaced with a 36 window assembly having a lower coefficient of heat transmittance, the 37 window and glazed areas may be reduced not more than twenty-five percent 38 below the minimum otherwise required by this paragraph. 39 (2) Where HVAC equipment is installed in an existing window, the 40 window and glazed areas may be reduced by not more than twenty-five 41 percent below the minimum otherwise required by this paragraph. 42 (3) Where both an existing window is replaced with a window assembly 43 in accordance with paragraph a of this subdivision and HVAC equipment is 44 installed in such window assembly, such window and glazed areas may be 45 reduced by not more than thirty-three percent below the minimum other- 46 wise required by this paragraph. 47 3. Whenever a basement conforming to the provisions of [subdivision 48 four of] section one hundred seventy-seven is permitted to be occupied 49 for living purposes, every living room, bathroom, water-closet compart- 50 ment, kitchen and cooking space therein shall have one or more windows 51 opening directly upon a street; or upon a yard which is at every point 52 at least fifteen feet in depth and, above the window sill level of the 53 first story above the basement, at least twenty feet; or upon a court at 54 least two feet in width and extending the entire depth of the lot from 55 the street to the yard. All such yards and courts shall be measured at 56 the ground level from the lot line to the building line opposite on the

52

S. 10200--A 6

53

1 same lot. The top edge of the glazed area of every window shall be nine 2 inches or more below the finished ceiling and one foot or more above the 3 level of the adjoining ground. Every such window shall be so constructed 4 that one-half or more of its area may be opened, and shall be so located 5 as to light and ventilate adequately all portions of the room. The 6 windows in each such room shall have an aggregate glazed area of at 7 least one-eighth of the total floor area of the room, and in no event 8 less than twelve square feet[. The top edge of the glazed area of every 9 window shall be nine inches or more below the finished ceiling and one 10 foot or more above the level of the adjoining ground. Every such window 11 shall be so constructed that one-half or more of its area may be opened, 12 and shall be so located as to light and ventilate adequately all 13 portions of the room] except that: 14 a. Where an existing window in any such room is replaced with a window 15 assembly having a lower coefficient of heat transmittance, the window 16 and glazed areas may be reduced not more than twenty-five percent below 17 the minimum otherwise required by this subdivision. 18 b. Where HVAC equipment is installed in an existing window, such 19 window and glazed areas may be reduced by not more than twenty-five 20 percent below the minimum otherwise required by this subdivision. 21 c. Where both an existing window is replaced with a window assembly in 22 accordance with paragraph a of this subdivision and HVAC equipment is 23 installed in such window assembly, such window and glazed areas may be 24 reduced by not more than thirty-three percent below the minimum other- 25 wise required by this subdivision. 26 § 13. Subdivision 2 of section 214 of the multiple dwelling law is 27 amended to read as follows: 28 2. In any tenement, apartments containing three or more rooms may have 29 dining bays, which shall not exceed fifty-five square feet in floor 30 surface area and shall not be deemed separate rooms or subject to the 31 requirements for separate rooms or alcoves. [Every] No dining bay shall 32 be permitted in any apartment containing less than three rooms. Where 33 permitted, such dining bay shall be equipped with such appropriate 34 permanent fittings as may be required by the department and shall also 35 be provided with at least one window opening directly upon a street or 36 upon a yard or court which was lawful on April eighteenth, nineteen 37 hundred twenty-nine. The area of such window shall be one-eighth at 38 least of the floor surface area of such dining bay[. No dining bay shall 39 be permitted in any apartment containing less than three rooms.], except 40 that: 41 a. Where an existing window in any such dining bay is replaced with a 42 window assembly having a lower coefficient of heat transmittance, such 43 window may be reduced by not more than twenty-five percent below the 44 minimum otherwise required by this subdivision. 45 b. Where HVAC equipment is installed in an existing window, the area 46 of such window may be reduced by not more than twenty-five percent below 47 the minimum otherwise required by this subdivision. 48 c. Where both an existing window is replaced with a window assembly in 49 accordance with paragraph a of this subdivision and HVAC equipment is 50 installed in such window assembly, the area of such window may be 51 reduced by not more than thirty-three percent below the minimum other- 52 wise required by this subdivision. 53 § 14. The opening paragraph and paragraph f of subdivision 2 of 54 section 216 of the multiple dwelling law, the opening paragraph as 55 amended by chapter 874 of the laws of 1956, are amended to read as 56 follows:

54

S. 10200--A 7

55

1 No room in the basement or cellar of any tenement shall be occupied 2 for living purposes unless there is a written permit therefor as 3 provided in [subdivision five of] section three hundred and it either is 4 part of an apartment which complies with the conditions of subdivision 5 six of section thirty-four or complies with the following conditions: 6 f. [The area of every] Every window in such a room shall be [at] made 7 to open, and the top of each window shall be within twelve inches of the 8 ceiling. At least twelve square feet, and the total area of windows in 9 every such room shall be at least one-eighth of the total floor area of 10 the room[. At least half of each window shall be made to open, and the 11 top of each window shall be within twelve inches of the ceiling], except 12 that: 13 (1) Where an existing window in any such room is replaced with a 14 window assembly having a lower coefficient of heat transmittance, such 15 window may be reduced by not more than twenty-five percent below the 16 minimum otherwise required by this paragraph. 17 (2) Where HVAC equipment is installed in an existing window, such 18 window area may be reduced by not more than twenty-five percent below 19 the minimum otherwise required by this paragraph. 20 (3) Where both an existing window is replaced with a window assembly 21 in accordance with subparagraph one of this paragraph and HVAC equipment 22 is installed in such window assembly, such window area may be reduced by 23 not more than thirty-three percent below the minimum otherwise required 24 by this paragraph. 25 § 15. Paragraph d of subdivision 3 of section 216 of the multiple 26 dwelling law is amended to read as follows: 27 d. Such room shall have a window or windows opening directly to the 28 required unoccupied area of ground outside of and adjoining such room or 29 to a street or yard. Every such window shall be made so as to open read- 30 ily and such window or windows shall provide at least twelve square feet 31 of clear openings for ventilation, except that where an existing window 32 is replaced with a window assembly having a lower coefficient of heat 33 transmittance, such window opening may provide not less than nine square 34 feet of clear openings for ventilation. 35 § 16. Paragraph b of subdivision 4 of section 216 of the multiple 36 dwelling law is amended to read as follows: 37 b. Such room shall be everywhere seven feet six inches or more in 38 height from floor to ceiling and shall have a window or windows opening 39 directly to a street, or to a yard at least twelve feet in depth, or to 40 a court at least six feet in its least dimension and twelve feet in its 41 greatest dimensions; every such windows shall be made so as to open 42 readily; such window or windows shall provide at least twelve square 43 feet of clear opening for ventilation, [and the] except that where an 44 existing window is replaced with a window assembly having a lower coef- 45 ficient of heat transmittance, such window may provide not less than 46 nine square feet of clear opening for ventilation. The apartment 47 containing such room shall have one or more rooms opening upon a street 48 or yard. 49 § 17. Subdivision 5 of section 217 of the multiple dwelling law is 50 amended to read as follows: 51 5. In every public hall that is provided with a window or windows in a 52 tenement erected after April twelfth, nineteen hundred one, at least one 53 such window shall be at least two feet six inches wide and five feet 54 high, except that: 55 a. Where an existing window is replaced with a window assembly having 56 a lower coefficient of heat transmittance, such window may be reduced in

56

S. 10200--A 8

57

1 area by not more than twenty-five percent below the minimum otherwise 2 required by this subdivision. 3 b. Where HVAC equipment is installed in an existing window, the glazed 4 area may be reduced by not more than twenty-five percent below the mini- 5 mum otherwise required by this subdivision. 6 c. Where both an existing window is replaced with a window assembly in 7 accordance with paragraph a of this subdivision and HVAC equipment is 8 installed in such window assembly, such glazed area may be reduced by 9 not more than thirty-three percent below the minimum otherwise required 10 by this subdivision. 11 § 18. Paragraph a of subdivision 11 of section 248 of the multiple 12 dwelling law is amended to read as follows: 13 a. No room may be occupied for sleeping purposes unless it has a 14 window or windows with an aggregate glazed area of at least ten per 15 centum of the total floor area of such room. Each such window shall be 16 at least twelve feet in area and so constructed that at least half of 17 its area may be opened, except that: 18 (1) Where an existing window in any such room is replaced with a 19 window assembly having a lower coefficient of heat transmittance, such 20 window and glazed areas may be reduced by not more than twenty-five 21 percent below the minimum otherwise required by this paragraph. 22 (2) Where HVAC equipment is installed in an existing window, such 23 window and glazed areas may be reduced by not more than twenty-five 24 percent below the minimum otherwise required by this paragraph. 25 (3) Where both an existing window is replaced with a window assembly 26 in accordance with subparagraph one of this paragraph and HVAC equipment 27 is installed in such window assembly, such window and glazed areas may 28 be reduced by not more than thirty-three percent below the minimum 29 otherwise required by this paragraph. 30 § 19. Subdivision 7 of section 277 of the multiple dwelling law, as 31 added by chapter 734 of the laws of 1985, paragraph (e) as amended by 32 chapter 559 of the laws of 1995, is amended to read as follows: 33 7. Minimum light and air standards for joint living-work quarters for 34 artists or general residential portions of lofts or manufacturing and 35 commercial buildings altered to residential use shall comply with the 36 following: 37 (a) Portions of such buildings which are occupied exclusively as joint 38 living-work quarters for artists as permitted by local law shall comply 39 with the following: 40 (i) The minimum size of a joint living-work quarters for artists shall 41 be twelve hundred square feet of interior space, except as otherwise 42 authorized by the zoning resolution of the city of New York, for units 43 occupied for residential purposes on or before January first, nineteen 44 hundred eighty-five. 45 (ii) Joint living-work quarters for artists shall conform to the stan- 46 dards for light and ventilation of former sections C26-1205.0 through 47 and including section C26-1205.7 of the administrative code of the city 48 of New York. 49 (b) Portions of such buildings which are occupied exclusively as resi- 50 dential units as permitted by local law shall comply with the following: 51 (i) Every dwelling unit shall have one or more windows: 52 A. which open onto a street, a court with a dimension of fifteen feet 53 perpendicular to the windows and one hundred square feet minimum area 54 above a setback or a thirty foot rear yard; or

58

S. 10200--A 9

59

1 B. for corner lots or lots within one hundred feet of a corner, where 2 the minimum horizontal distance between such windows opening onto a rear 3 yard and the rear lot line is at least twenty feet; or 4 C. for interior lots, where the minimum horizontal distance between 5 such windows opening onto a rear yard and any wall opposite such windows 6 on the same or another zoning lot is at least twenty feet and not less 7 than a distance equal to one-third of the total height of such wall 8 above the sill height of such windows; but need not exceed forty feet; 9 or 10 D. for interior lots where the minimum horizontal distance between 11 such windows opening onto a rear yard and any wall opposite such windows 12 on the same or another zoning lot is at least fifteen feet and the mini- 13 mum size of such dwelling unit is twelve hundred square feet; or 14 E. in no event shall the distance between such windows and the rear 15 lot line be less than five feet; and 16 F. yards and courts may be existing or may be new in buildings seven 17 stories or less in height. 18 (ii) The minimum required ratio of window area opening onto a street, 19 rear yard, or court to the floor area of every living room shall: 20 A. be ten percent where the floor area of such living room is less 21 than five hundred square feet, except that: 22 (1) where an existing window in any such room is replaced with a 23 window assembly having a lower coefficient of heat transmittance, such 24 window areas may be reduced not more than twenty-five percent below the 25 minimum otherwise required by this paragraph; 26 (2) where HVAC equipment is installed in an existing window, such 27 window area may be reduced by not more than twenty-five percent below 28 the minimum otherwise required by this paragraph; or 29 (3) where both an existing window is replaced with a window assembly 30 in accordance with item one of this clause, and HVAC equipment is 31 installed in such window, such window area may be reduced by not more 32 than thirty-three percent below the minimum otherwise required by this 33 paragraph; or 34 B. decrease, by one percent for every one hundred square feet greater 35 than five hundred square feet of floor area of such living room, to a 36 minimum of five percent; and 37 C. in no event shall the distance between such window area and the 38 rear lot line be less than five feet; and 39 D. at least fifty percent of the required window area shall be opena- 40 ble. 41 (c) Ventilation of spaces other than living rooms, including enclosed 42 work spaces for joint living-work quarters for artists shall be either 43 in accordance with this section or in accordance with the administrative 44 code of the city of New York. 45 (d) No building converted pursuant to this article shall be enlarged, 46 except where the underlying zoning district permits residential use. 47 Such an enlargement shall be in conformance with the bulk regulations 48 for conforming residential use for new construction and shall be in 49 conformance with the provisions of section twenty-six of this chapter. 50 No interior floor area enlargement shall be permitted except that a 51 mezzanine with a minimum headroom of seven feet shall be allowed within 52 individual dwelling units, provided that the gross floor area of such 53 mezzanine does not exceed one-third of the floor area contained within 54 such dwelling unit. No mezzanine shall be included as floor area for the 55 purpose of calculating the minimum required size of a living room or a 56 dwelling unit or for calculating floor area devoted to dwellings. For

60

S. 10200--A 10

61

1 the purpose of this article a mezzanine may be constructed above the 2 level of the roof of a building as long as the aggregate area of roof 3 structures does not exceed one-third of the total roof area and the roof 4 structures conform with applicable building code requirements. 5 (e) The kitchen located within dwelling units and having a floor area 6 of eighty square feet or more shall have natural ventilation as 7 prescribed in sections 27-749 and 27-750 of chapter twenty-seven of the 8 administrative code of the city of New York. Open kitchens shall be 9 considered as part of the adjacent space where forty percent of the area 10 of the separation between the spaces is open and without doors. If the 11 floor area of the combined space exceeds seven hundred fifty square 12 feet, a separate bedroom shall not be required. When the floor area is 13 less than eighty square feet the kitchenette shall be ventilated by 14 either of the following: 15 (i) Natural means complying with sections 27-749 and 27-750 of chapter 16 twenty-seven of the administrative code of the city of New York and 17 further that the windows shall have a minimum width of twelve inches, a 18 minimum area of three square feet, or ten percent of the floor area of 19 the space, whichever is greater and be so constructed that at least 20 one-half of their required area may be opened, except that where exist- 21 ing windows are replaced with window assemblies having a lower coeffi- 22 cient of heat transmittance, such windows may be reduced to not less 23 than a minimum width of ten inches, a minimum area of two and one-quar- 24 ter square feet, or one-twelfth of the floor area of the space, whichev- 25 er is greater. When the space is located at the top story, the window 26 or windows may be replaced with a skylight whose minimum width shall be 27 twelve inches, whose minimum area shall be four square feet or one- 28 eighth of the floor area of the space, whichever is greater and which 29 shall have ventilation openings of at least one-half of the required 30 area of the skylight. 31 (ii) Mechanical means exhausting at least two cubic feet per minute of 32 air per square foot of floor area. Where doors are to be used to sepa- 33 rate the space, the lower portion of each door shall have a metal grill 34 containing at least forty-eight square inches of clean openings or in 35 lieu of such grill, two clear opening spaces may be provided, each of at 36 least twenty-four square inches, one between the bottom of each door and 37 the floor and the other between the top of each door and the head jamb. 38 (f) When bathrooms and toilet rooms are ventilated by natural means, 39 the natural ventilation sources shall comply with former sub-article 40 1205.0 of chapter twenty-six of the administrative code of the city of 41 New York and shall have an unobstructed free area of at least five 42 percent of the floor area. In no case shall the net free area of the 43 ventilation sources be less than one and one-half square feet. When 44 bathrooms and toilet rooms are vented by mechanical means, individual 45 vent shafts or ducts constructed of non-combustible materials with a 46 minimum cross section area of one square foot shall be utilized, the 47 exhaust system shall be capable of exhausting at least fifty cubic feet 48 per minute of air. Means shall be provided for egress of air by louvers 49 in doors, by undercutting the door, or by transfer ducts, grills or 50 other openings. Toilet exhaust systems shall be arranged to expel air 51 directly to the outdoors. 52 (g) A single station smoke detector shall be installed immediately 53 outside each sleeping or bedroom area of each dwelling unit. Such device 54 shall be designed and installed so as to detect smoke and activate an 55 alarm, be reasonably free from false alarms and provide visible indi- 56 cation that the alarm is energized. Such device shall be directly

62

S. 10200--A 11

63

1 connected to the lighting circuit of the dwelling or rooming unit with 2 no intervening wall switch and shall provide a warning signal clearly 3 audible in all sleeping quarters with intervening doors closed. Cord 4 connected installations or smoke detectors which rely exclusively on 5 batteries are not permissible. Such devices shall either be approved or 6 listed by an acceptable testing service or laboratory. 7 § 20. This act shall take effect immediately and shall apply to all 8 buildings in existence on or constructed after such date.

64

Go to top