  "id": "dorworth:recall:fda-z-0360-2027",
  "kind": "recall",
  "schemaVersion": 1,
  "schema": "https://dorworth.com/schemas/v1/recall.json",
  "url": "https://dorworth.com/relationships-family/recalls/fda-z-0360-2027",
  "title": "W L Gore & Associates, Inc.: Brand Name: GOREÂ¿ VIABAHNÂ¿ Endoprosthesis with Heparin Bioactive Surface, GOREÂ¿ VIABAHNÂ¿ Endoprosthesis with PROPATEN Bioactive Surface …",
  "place": [
    {
      "scope": "nation",
      "code": "US",
      "name": "United States"
    }
  ],
  "source": {
    "body": "Food and Drug Administration",
    "url": "https://api.fda.gov/device/enforcement.json?search=recall_number:%22Z-0360-2027%22",
    "retrievedAt": "2026-11-25T02:45:38.127-05:00"
  },
  "keptCopy": null,
  "published": "2026-11-25T02:45:38.127-05:00",
  "updated": "2026-11-25T02:45:38.127-05:00",
  "changes": {
    "count": 0,
    "url": "https://dorworth.com/changes?record=dorworth%3Arecall%3Afda-z-0360-2027"
  },
  "terms": {
    "credit": "Dorworth News",
    "url": "https://dorworth.com/terms"
  },
  "body": {
    "identifier": "Z-0360-2027",
    "issuedOn": "2026-11-18",
    "issuedBy": "Food and Drug Administration",
    "status": "listed",
    "sourcePage": "https://api.fda.gov/device/enforcement.json?search=recall_number:%22Z-0360-2027%22",
    "sourceFile": null,
    "copyNote": "The Food and Drug Administration’s record of the recall is its data, not a document: its record here is the data as read.",
    "history": [],
    "agency": "fda",
    "category": "other",
    "firm": "W L Gore & Associates, Inc.",
    "product": "Brand Name: GOREÂ¿ VIABAHNÂ¿ Endoprosthesis with Heparin Bioactive Surface, GOREÂ¿ VIABAHNÂ¿ Endoprosthesis with PROPATEN Bioactive Surface Product Name: GOREÂ¿ VIABAHNÂ¿ Endoprosthesis with Heparin Bioactive Surface, GOREÂ¿ VIABAHNÂ¿ Endoprosthesis with PROPATEN Bioactive Surface Model/Catalog Number: VBJR081002A, VBJR081502A, VBJR060702A, VBJR071002A, PAJR081002B, VBJR080702A, VBJR072502A, VBJR082502A, PAHR131002B, PAJR071002B, VBJR080502A, VBJR061502A, VBJR051502A, VBJR062502A, VBHR111002A, VBJR052502A, VBJR051002A, VBHR110502A, VBHR131002A, VBHR131002H, VBHR110502W, VBHR131002W, JHJR060702J, JHJR071002J, PAJR081002E, PAHR131002E, PAJR061502E, PAJR070502E, PAJR071002E, PAJR062502E, PAJR061002E, PAJR051502E, PAJR070702E, PAHR110502E, PAHR130502E Reference Attachment 6 for an explanation of the part numbers. Product Description: The GOREÂ¿ VIABAHNÂ¿ Endoprosthesis with Heparin/PROPATEN Bioactive Surface is intended for use as an endovascular prosthesis. The endoprosthesis functions as a new blood conduit, with inlet and outlet to the endoprosthesis for blood flow. The self-expanding stent frame serves to maintain an open vessel lumen while the expanded polytetrafluoroethylene (ePTFE) graft material serves as a blood flow conduit. Surface bound heparin on the device is used as an anticoagulant to provide thromboresistance. The GOREÂ¿ VIABAHNÂ¿ Endoprosthesis with Heparin/PROPATEN Bioactive Surface is a flexible, self-expanding endoluminal endoprosthesis consisting of an ePTFE lining with an external nitinol (NiTi = Nickel:Titanium) support extending along its entire length. Four radiopaque markers are present on each end of the endoprosthesis to facilitate accurate placement and improve visibility of the device post-deployment. The CBASÂ¿ Heparin Surface on the GOREÂ¿ VIABAHNÂ¿ Endoprosthesis with Heparin/PROPATEN Bioactive Surface consists of stable, covalent, end-point attached heparin of porcine origin. The endoprosthesis is compressed and attached to a dual lumen delivery catheter. The larger central catheter lumen is used for flushing and guidewire introduction. The smaller lumen contains elements of the deployment mechanism. The delivery catheter hub assembly has one port for the deployment system and one port for flushing and guidewire insertion. To facilitate accurate endoprosthesis placement, two radiopaque metallic bands are attached to the catheter shaft, marking the ends of the compressed endoprosthesis. Component: N/A",
    "hazard": "Endovascular prosthesis were manufactured on equipment that was not operating with valid parameters and may cause the distal tip to separate.",
    "remedy": null,
    "units": "424",
    "classification": "Class II",
    "recallStatus": "Ongoing",
    "notes": [
      {
        "text": "Worldwide - US Nationwide distribution including in the states of AL, AR, AZ, CA, CO, DC, DE, FL, GA, IA, ID, IL, IN, KS, KY, LA, MA, MD, MI, MN, MO, NC, ND, NE, NJ, NV, NY, OH, OK, OR, PA, SC, SD, TN, TX, UT, VA, WA, WI, and WV. The countries of Argentina, Austria, Belgium, Canada, France, Germany, Israel, Italy, Japan, Netherlands, Poland, Saudi Arabia, Slovenia, South Africa, Spain, Sweden, Switzerland, Taiwan, Turkey, and United Kingdom.",
        "label": "Distribution"
      },
      {
        "text": "Voluntary: Firm initiated",
        "label": "Who started it"
      }
    ]
  }
}